SOP of Operation & Cleaning of Tablet Disintegration Tester

OBJECTIVE: The purpose of this standard Operating procedure (SOP) is to lay down a procedure for operation and cleaning of Tablet Disintegration Tester. SCOPE: This Sop is applicable to operate the Double Basket Tablet Disintegration Tester in IPQC area of manufacturing department at manufacturing facility of XXX Make: Lab India Analytical instruments Pvt. Ltd. RESPONSIBILITY: […]

SOP of Operation & Cleaning of Tablet Disintegration Tester Read More »

SOP For cleaning & numbering procedure for containers and SS accessories.

OBJECTIVE: The purpose of this SOP is to provide a procedure for the cleaning & numbering procedure for containers and SS accessories. SCOPE: This SOP is applicable to cleaning & numbering procedure for container and SS accessories at manufacturing facility of XXX.    RESPONSIBILITY: Authorized designee of Production shall be responsible for cleaning & numbering procedure

SOP For cleaning & numbering procedure for containers and SS accessories. Read More »

SOP for Handling of Tool-Kit

OBJECTIVE: The purpose of this SOP is to provide a procedure for handling of tool-kit. SCOPE: This SOP is applicable to specifies handling of tool-kit at manufacturing facility of XXX RESPONSIBILITY: Authorized designee of Production/Packaging Staff shall be responsible for handling of tool-kit. Head of Production/Packaging responsible for effective implementation of SOP. PROCEDURE: Precaution:   Ensure

SOP for Handling of Tool-Kit Read More »

SOP For Operation of Oscillating Granulator

The purpose of this standard Operating Procedure (SOP) is to lay down a procedure for operation of Oscillating Granulator. SCOPE: This SOP is applicable for the operation of Oscillating Granulator at manufacturing facility. RESPONSIBILITY: 3.1                 Officer/ Executive shall be responsible for operation of Oscillating Granulator Head of production department shall be responsible for effective implementation

SOP For Operation of Oscillating Granulator Read More »

SOP of Operation and Calibration of Moisture Balance

The purpose of this standard Operating Procedure (SOP) is to lay down a procedure for operation of moisture balance. SCOPE: This procedure is applicable for moisture balance in manufacturing department of Production area at manufacturing facility. Make: Contech  (Modal:CBB-50,Capacity : 50 gm) RESPONSIBILITY: 3.1                 Officer/ Executive shall be responsible for operation of moisture balance. 3.2                

SOP of Operation and Calibration of Moisture Balance Read More »

Supporting Clean Areas & Clean Areas Separation in Aseptic Product Manufacturing – USFDA

Supporting Clean Areas Supporting clean areas can have various classifications and functions.  Many support areas function as zones in which nonsterile components, formulated products, in-process materials, equipment, and container/closures are prepared, held, or transferred.  These environments are soundly designed when they minimize the level of particle contaminants in the final product and control the microbiological

Supporting Clean Areas & Clean Areas Separation in Aseptic Product Manufacturing – USFDA Read More »

Sterile Product Building, Facility and Clean Area Classification Guideline By USFDA

Sterile Product Building, Facility and  Clean Area Classification Guideline By USFDA has clearly mentioned what conditions to be followed to maintain the Sterile Conditions in Sterile Product Manufacturing site. 21 CFR 211.42(b) states, in part, that “The flow of components, drug product containers, closures, labeling, in-process materials, and drug products through the building or buildings

Sterile Product Building, Facility and Clean Area Classification Guideline By USFDA Read More »

TEST FOR SPECIFIED MICRO-ORGANISMS (Ph. Eur. method 2.6.13.)

TEST FOR SPECIFIED MICRO-ORGANISMS (Ph. Eur. method 2.6.13.) INTRODUCTION The tests described hereafter will allow determination of the absence or limited occurrence of specified micro-organisms that may be detected under the conditions described. The tests are designed primarily to determine whether a substance or preparation complies with an established specification for microbiological quality. When used

TEST FOR SPECIFIED MICRO-ORGANISMS (Ph. Eur. method 2.6.13.) Read More »

SOP For Operation, Maintenance And Calibration Of Ultrasonic Water Bath

The purpose of this Standard Operating Procedure (SOP) is to lay down the procedure for Operation, maintenance and Calibration of Ultrasonic Water Bath. PROCEDURE: PRELIMINARY CHECK: Fill the Water bath with water up to height of minimum 7cm from bottom of tank. Whenever the Ultrasonic Water Bath is required with specific temperature then heater to

SOP For Operation, Maintenance And Calibration Of Ultrasonic Water Bath Read More »

Sterile Drug Products Produced by Aseptic Processing – USFDA Guideline for Buildings & Facilities

21 CFR 211.42(b) states, in part, that “The flow of components, drug product containers, closures, labeling, in-process materials, and drug products through the building or buildings shall be designed to prevent contamination.”21 CFR 211.42(c) states, in part, that “Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined

Sterile Drug Products Produced by Aseptic Processing – USFDA Guideline for Buildings & Facilities Read More »