ICH Q3D Elemental Impurities Risk Assessment: Step-by-Step Guide

Last reviewed 26 Nov 2026 · 10 min read

Contents
  1. What ICH Q3D is
  2. Why it matters
  3. The element classes
  4. The risk assessment in three steps
  5. Step 1: Identify the sources
  6. Step 2: Collect data and evaluate
  7. Step 3: Compare with the control threshold
  8. Risk assessment worksheet
  9. Worked example (fictional)
  10. Common mistakes
  11. Related quality systems
  12. Frequently asked questions
  13. Do I have to test every batch for elemental impurities?
  14. What is the difference between PDE and the control threshold?
  15. Do biotech products need an elemental impurity assessment?
  16. References

In short: An ICH Q3D risk assessment checks every possible source of toxic metals in a finished drug product, adds up the expected amount per day and compares it with the permitted daily exposure (PDE) for each element. If the total is consistently below 30% of the PDE, no extra control is needed; if not, you set controls. This guide gives the steps, a printable worksheet and a fictional worked example for freshers in QA, QC and regulatory affairs.

What ICH Q3D is

ICH Q3D is the harmonised guideline for elemental impurities in drug products, such as lead, arsenic, cadmium, mercury, nickel or leftover catalyst metals. The current version is Q3D(R2), adopted on 26 April 2022. It has three parts: toxicity evaluation of each element, a PDE (the maximum quantity of an element a patient may take per day), and a risk-based approach to control.

The guideline applies to new finished drug products, including products containing purified proteins and synthetic peptides. It does not apply to herbal products, radiopharmaceuticals, vaccines, gene or cell therapy products, or products used only in clinical research stages, among others (Section 2). Elements added on purpose for a therapeutic benefit are also outside its scope.

Why it matters

Elemental impurities give the patient no benefit, so they must stay within safe limits. They are rarely added on purpose. They come in with mined excipients, leach from containers, or are picked up from equipment. A written, documented risk assessment is how a manufacturer shows that it has looked at all these routes and decided what controls are needed.

The element classes

Q3D (Section 4) sorts elements by toxicity and by how likely they are to occur in a drug product:

ClassElementsWhat it means for the assessment
1As, Cd, Hg, PbAlways evaluate, for all routes and all sources
2ACo, Ni, VAlways evaluate, for all routes and all sources
2BAg, Au, Ir, Os, Pd, Pt, Rh, Ru, Se, TlEvaluate only if intentionally added (for example as a catalyst)
3Ba, Cr, Cu, Li, Mo, Sb, SnOral: only if intentionally added. Parenteral and inhalation: evaluate unless the route-specific PDE is above 500 µg/day

Table 5.1 in the guideline turns this into a yes/no grid by route. In short, for an oral product the minimum list is Class 1 plus Class 2A (As, Cd, Hg, Pb, Co, Ni, V), plus any element you added intentionally. For parenteral and inhalation products the minimum list also includes the Class 3 elements as set out in Table 5.1.

The risk assessment in three steps

Section 5.1 describes the process as three steps, often done together and repeated as data improves:

  1. Identify known and potential sources of elemental impurities.
  2. Evaluate by finding the observed or predicted level and comparing it with the PDE.
  3. Summarise and document the outcome, and decide whether existing controls are enough.

Step 1: Identify the sources

Section 5.2 lists four broad source groups. Check each one for every product:

  • Intentionally added elements: catalysts and inorganic reagents used to make the drug substance, excipients or other components.
  • Drug substance, water and excipients: trace metals not added on purpose, especially in mined materials.
  • Manufacturing equipment: depends on what contacts the product, and is reduced by equipment selection, qualification and GMP.
  • Container closure systems: metals that may leach into the product.

Purified water or water for injection that meets pharmacopoeial requirements helps reduce the risk from water.

Step 2: Collect data and evaluate

Section 5.5 allows several data sources: prior knowledge, published literature, data from similar processes, supplier information, testing of components, and testing of the drug product. Supplier declarations are useful, so a good vendor management system should ask excipient and API suppliers for elemental impurity data.

Where testing is needed, the method must be fit for purpose. See our guide on analytical method validation under ICH Q2. USP general chapters <232> and <233> are widely used alongside Q3D for limits and procedures.

Convert PDEs into concentrations if that helps. Section 7 gives the options:

  • Option 1: common limits (µg/g) for every component, assuming a daily intake of not more than 10 g. The values are listed in Table A.2.2.
  • Option 2a: the same idea, but using the product’s actual maximum daily intake.
  • Option 2b: component-specific limits, shown to keep the total within the PDE by summing the contribution of each component.
  • Option 3: measuring each element in the finished product and comparing it with a limit calculated from the maximum total daily dose.

The basic equation is: concentration (µg/g) = PDE (µg/day) ÷ maximum daily intake of the product (g/day).

Step 3: Compare with the control threshold

Section 5.6 defines the control threshold as 30% of the established PDE. If the total from all sources is expected to be consistently less than 30% of the PDE, and the data are properly assessed, additional controls are not required. Otherwise, controls must be put in place so the PDE is not exceeded.

Variability matters: the analytical method, the source materials and the finished product can all vary. Unless there is other justification, the guideline says level and variability can be shown with data from three representative production-scale lots or six representative pilot-scale lots. Mined excipients may need more data.

Controls (Section 6) include changing a process step, in-process or upstream controls, specifications for excipients, drug substance or drug product, and choosing a suitable container closure system.

Risk assessment worksheet

Use this example worksheet for each product. Make one copy per route of administration.

ElementClassIntentionally added? (Y/N)Source (DS / excipient / water / equipment / container)Data type and referenceLevel (µg/g or µg/day)Total µg/dayPDE µg/day% of PDEBelow 30%?Control needed

Add a header block with product name, strength, route, maximum daily dose, batch size, prepared by, date, reviewer and version. Keep the signed worksheet and its supporting data with the other quality records, for at least 1 year after the expiry of the respective product batch (EU GMP Chapter 4 §4.11; 21 CFR 211.180(a)).

Worked example (fictional)

This example is invented for teaching and does not describe a real product or supplier.

Product: Exampletab 500 mg film-coated tablet, oral. Maximum daily dose: 4 tablets, so 2.000 g of tablet per day. The drug substance is made with a palladium catalyst. The tablets are packed in HDPE bottles.

Step 1, elements to assess: Class 1 (As, Cd, Hg, Pb), Class 2A (Co, Ni, V) because the route is oral, and Pd because it is intentionally added in synthesis.

Step 2, daily composition and data. Concentrations are example values from supplier certificates and an ICP-MS check, in µg/g.

Componentg per daily dosePbCdAsHgCoVNi
Drug substance1.0000.10.10.20.050.50.54
Microcrystalline cellulose0.7000.10.050.10.020.10.10.5
Croscarmellose sodium0.1200.20.050.10.020.10.10.5
Talc0.1001.50.41.00.12340
Magnesium stearate0.0400.50.10.20.020.20.11
Film coat0.0400.80.10.20.020.20.52

Each contribution is mass (g) × concentration (µg/g). For lead: 1.000 × 0.1 = 0.100; 0.700 × 0.1 = 0.070; 0.120 × 0.2 = 0.024; 0.100 × 1.5 = 0.150; 0.040 × 0.5 = 0.020; 0.040 × 0.8 = 0.032. The total is 0.396 µg/day.

For nickel the same arithmetic gives 8.53 µg/day from components. In this example, an equipment assessment adds an estimated 10 µg/day from stainless-steel contact parts, so the total is 18.53 µg/day. The HDPE bottle is assessed as not contributing any listed element.

For palladium, only the drug substance matters. Three production-scale lots of the drug substance show 18, 22 and 29 µg/g. Using the highest value: 1.000 g × 29 µg/g = 29 µg/day.

Step 3, compare with PDE and the 30% threshold:

ElementTotal (µg/day)Oral PDE (µg/day)% of PDEBelow 30%?
Pb0.39657.9%Yes
Cd0.18953.8%Yes
As0.398152.7%Yes
Hg0.078300.3%Yes
Co0.798501.6%Yes
V0.9061000.9%Yes
Ni18.532009.3%Yes
Pd2910029%Only just

Conclusions. For Pb, Cd, As, Hg, Co, V and Ni, no additional control is needed beyond routine supplier qualification and change control. The risk assessment is documented and reviewed when a supplier or process changes.

For Pd, 29% is under the threshold but too close to it, given method and lot variability. In this example, the team sets a drug substance specification of not more than 50 µg/g Pd (an example in-house criterion). This equals the Option 2a common limit for a 2.000 g daily intake (100 µg/day ÷ 2.000 g = 50 µg/g) and keeps the maximum possible Pd exposure within the PDE.

A useful lesson: the Option 1 limit for lead is 0.5 µg/g, and the talc here has 1.5 µg/g. Under Option 1 that talc would not pass. Because the actual intake is only 2.000 g and the talc is only 0.100 g of the dose, the summed exposure is still far below the PDE. This is why a calculation based on the real composition (Option 2b style) is often more useful than a blanket limit.

Common mistakes

  • Skipping Class 2B elements when a catalyst was in fact used in the synthesis.
  • Assessing only the drug substance and forgetting excipients, equipment and the container closure system.
  • Using a PDE for the wrong route; oral, parenteral and inhalation values differ.
  • Treating “below the limit of quantitation” as zero without stating the assumption.
  • Using one lot of data for mined excipients, which vary naturally.
  • Not repeating the assessment after a change of supplier, process or packaging. This links directly to your change management system.
  • Mixing up the PDE (µg/day for the patient) with a concentration limit (µg/g in a component).

Q3D expects the assessment to follow quality risk management; see our article on quality risk management in the pharmaceutical industry. Equipment contribution sits alongside cleaning validation, though the two answer different questions. For roles in this area, see jobs for freshers.

Frequently asked questions

Do I have to test every batch for elemental impurities?

No. Q3D says testing is only applied when the risk assessment shows it is the right control. Many products are controlled through supplier information, specifications and process knowledge.

What is the difference between PDE and the control threshold?

The PDE is the toxicologically based daily limit. The control threshold is 30% of that PDE and is a decision point: below it (consistently), no extra control is required.

Do biotech products need an elemental impurity assessment?

Yes, the finished drug product is in scope. Section 5.7 notes that the risk at the drug substance stage is generally low, but excipients and environmental sources in drug product manufacture still need to be assessed.

References

  • ICH. Q3D(R2) Guideline for Elemental Impurities, Final version, adopted 26 April 2022. Sections 2, 4, 5 (5.1–5.7), 6, 7 and 10; Table 5.1; Appendix 2, Tables A.2.1 and A.2.2; Appendix 5.
  • ICH. Q9(R1) Quality Risk Management (2023); Q10 Pharmaceutical Quality System (2008).
  • USP general chapters <232> Elemental Impurities: Limits and <233> Elemental Impurities: Procedures.
  • European Commission. EudraLex Volume 4, Chapter 4: Documentation, §4.11. 21 CFR 211.180(a).

Related articles