In short: Residual solvents are organic volatile chemicals left over from making drug substances, excipients or drug products. ICH Q3C sorts them into three classes by toxicity and gives a permitted daily exposure (PDE) for each. QC analysts check results against these limits, usually by gas chromatography, using Option 1 (ppm limits) or Option 2 (a limit based on the actual daily dose).

What residual solvents are

ICH Q3C defines residual solvents as organic volatile chemicals that are used or produced in the manufacture of drug substances or excipients, or in the preparation of drug products. Practical manufacturing techniques do not remove them completely.

The guideline gives a simple reason for controlling them: residual solvents give the patient no therapeutic benefit. They should be removed as far as possible, and a product should not contain more than the safety data can support.

The current version is ICH Q3C(R9), Step 4 version dated 24 January 2024. The R9 revision changed section 3.4, so that the effect of solvent volatility on the analytical method is considered during validation.

What is in scope

  • Residual solvents in drug substances, excipients and drug products are covered.
  • Testing is needed when the production or purification process is known to leave such solvents. You only test for solvents that are actually used or produced.
  • The guideline does not cover solvents used on purpose as excipients, or solvates, although their content should be evaluated and justified.
  • It states that it does not apply to products in clinical research stages or to existing marketed products. Indian and other regulators, and pharmacopoeial requirements, may still expect compliance, so follow your market’s rules.
  • It applies to all dosage forms and routes. Higher levels may be acceptable for short-term use (30 days or less) or topical use, justified case by case.

The three classes

ClassMeaningExamples (as listed in the guideline)
Class 1Solvents to be avoided: known or strongly suspected human carcinogens and environmental hazardsBenzene, carbon tetrachloride, 1,2-dichloroethane
Class 2Solvents to be limited: non-genotoxic animal carcinogens or agents of other irreversible toxicity (such as neurotoxicity), or solvents with other significant but reversible toxicityAcetonitrile, methanol, dichloromethane, toluene, hexane
Class 3Solvents with low toxic potential; no health-based limit neededEthanol, acetone, ethyl acetate, 2-propanol, heptane

Class 3 solvents have PDEs of 50 mg per day or more. The guideline also has a short list (Table 4) of solvents with no adequate toxicological data, such as petroleum ether and trifluoroacetic acid. For these, the manufacturer must supply a justification for the residual level.

Example limits from the guideline

These values are taken from Q3C(R9). Always check the current guideline before using them in a specification.

Class 1 (Table 1)

SolventLimit (ppm)
Benzene2
Carbon tetrachloride4
1,2-Dichloroethane5
1,1-Dichloroethene8
1,1,1-Trichloroethane1500

Benzene and the others in this table are only acceptable if their use is unavoidable to make a product with a significant therapeutic advance.

Class 2 (Table 2), a few examples

SolventPDE (mg/day)Option 1 limit (ppm)
Acetonitrile4.1410
Dichloromethane6.0600
Hexane2.9290
Methanol30.03000
Toluene8.9890

Class 3: the guideline considers 50 mg per day or less (5000 ppm or 0.5% under Option 1) acceptable without justification. Higher amounts may be acceptable if realistic for manufacturing capability and GMP.

Note that the guideline gives PDEs to the nearest 0.1 mg/day and concentrations to the nearest 10 ppm, and says these values do not reflect the analytical precision needed. Precision is established during method validation.

Option 1 and Option 2

Both options use the same equation, where PDE is in mg/day and the dose is in g/day:

Concentration (ppm) = 1000 × PDE ÷ dose

Option 1 uses the ppm limits in Table 2. They were calculated by assuming a product mass of 10 g taken daily. They are acceptable for all substances, excipients and products, so Option 1 suits cases where the daily dose is not known or fixed. If every drug substance and excipient meets its Option 1 limit, they can be used in any proportion, provided the daily dose does not exceed 10 g. Products dosed above 10 g per day should be considered under Option 2.

Option 2 does not require every component to meet Option 1. You use the PDE in mg/day with the known maximum daily dose. You can add up the solvent contributed by each component; the total per day must be below the PDE. The guideline adds a condition: Option 2 limits are acceptable if it has been shown that the solvent is reduced to the practical minimum, and the limits should be realistic in relation to analytical precision, manufacturing capability and normal process variation.

Worked example (fictional)

In this example, a tablet has a maximum daily mass of 5.0 g and toluene is the solvent of concern. The toluene PDE is 8.9 mg/day, so the Option 1 limit is 890 ppm. The toluene contents below are made-up results.

ComponentAmount per dayToluene foundDaily exposure
Drug substance3.0 g2000 ppm3.0 g × 2000 ppm = 6.0 mg
Excipient 11.0 g400 ppm0.4 mg
Excipient 21.0 g200 ppm0.2 mg
Drug product5.0 g6.6 mg

Product concentration = 6.6 mg ÷ 5.0 g = 1.32 mg/g, which is 1320 ppm.

  • Option 1: the drug substance (2000 ppm) and the product (1320 ppm) are above 890 ppm, so Option 1 is not met.
  • Option 2: total daily exposure is 6.6 mg, which is below the PDE of 8.9 mg/day (about 74% of the PDE), so the limit is met, provided the practical-minimum condition above is shown.

If the total had been above 8.9 mg/day, the guideline says the finished product could be tested to see whether the process reduced the solvent, or other steps taken to cut the level.

QC workflow for residual solvents

  1. List the solvents. From the manufacturing process, list every solvent used or produced, especially in the final step and in earlier steps where removal is not consistently proven. Get this from the supplier information and the process description.
  2. Classify each solvent against Tables 1 to 4 of the current guideline, and write the class and limit in the specification.
  3. Choose Option 1 or Option 2 for Class 2 solvents and record the calculation. For Class 3 only, a non-specific method such as loss on drying can be used if properly validated.
  4. Select the method. Residual solvents are usually determined by chromatography such as gas chromatography. The guideline says to use harmonised pharmacopoeial procedures where feasible (for instance the approach in USP general chapter <467>, using the current version). Otherwise use a validated procedure of your choice.
  5. Validate or verify the method following ICH Q2, considering solvent volatility. See analytical method validation (ICH Q2).
  6. Run the system suitability and sample sequence on a qualified, well-maintained instrument. See GC troubleshooting in quality control and the good chromatography practices SOP.
  7. Calculate and compare results with the limit, in ppm and, for Option 2, in mg/day.
  8. Report with the solvent name, class, result, limit and method reference. Investigate out-of-specification results as per your site procedure.
  9. Keep records at least 1 year after the expiry of the respective product batch (EU GMP Chapter 4 §4.11; 21 CFR 211.180(a)).

What suppliers report

Q3C gives acceptable examples of statements a supplier of an excipient or drug substance can make, for instance:

  • Only Class 3 solvents are likely to be present, and loss on drying is less than 0.5%.
  • Only named Class 2 solvents are likely to be present, all below the Option 1 limit.
  • Named Class 2 solvents and Class 3 solvents are likely to be present, with Class 2 below Option 1 and Class 3 below 0.5%.

“Likely to be present” refers to the solvent used in the final manufacturing step and solvents from earlier steps not removed consistently by a validated process. Class 1 solvents, if likely to be present, should be identified and quantified. So should Class 2 or Class 3 solvents present above their Option 1 limit or 0.5% respectively.

The guideline also allows a cumulative calculation for the drug product from the levels in its ingredients. If the calculated level is at or below the recommended level, product testing need not be considered. If a solvent is used during product manufacture, the product should be tested.

Example reporting template

This example table can be adapted for a certificate or worksheet. Limits are filled from the current guideline; other entries are blank.

SolventClassLimit (ppm or mg/day)Option usedResultMeets limit?Analyst / date
Toluene (example)2890 ppm (Option 1)1

Common mistakes

  • Using Option 1 limits for a product dosed above 10 g per day.
  • Treating Class 3 as “no control needed” and not recording the loss on drying or result.
  • Testing for solvents that are never used, or missing a solvent used in an earlier step that is not reliably removed.
  • Applying the Option 2 PDE without checking the actual maximum daily dose.
  • Using an old copy of the guideline. PDEs have been revised before, for example for tetrahydrofuran and N-methylpyrrolidone.
  • Ignoring volatility effects when preparing standards and samples in the method.

Frequently asked questions

Is Q3C(R9) the latest version?

At the time of checking, R9 (24 January 2024) is the current Step 4 version on the ICH website. Check the ICH site before issuing specifications.

What is the difference between PDE and ppm limit?

PDE is the maximum acceptable intake per day in mg. The ppm limit is the PDE converted to a concentration using an assumed daily mass, 10 g in Option 1.

Can I use loss on drying instead of GC?

The guideline allows a non-specific method such as loss on drying only if just Class 3 solvents are present and the method is properly validated.

Does Q3C cover elemental impurities?

No. Metal impurities are covered by ICH Q3D. See ICH Q3D elemental impurities risk assessment.

Where do residual solvents fit in a specification?

They are one of the impurity-related tests. See specifications, test procedures and acceptance criteria.

For more QC roles and openings, see /jobs/.

References

  • ICH. Impurities: Guideline for Residual Solvents Q3C(R9), Step 4 version, 24 January 2024. Official PDF. Sections 1 to 4, Tables 1 to 4.
  • ICH. Q2 Validation of Analytical Procedures (current version).
  • USP general chapter <467> Residual Solvents.
  • European Commission. EudraLex Volume 4, Chapter 4: Documentation, §4.11. 21 CFR 211.180(a).

Related articles