SOP for Label Control and Status Labels in Manufacturing
Contents
- What the regulators expect
- Example SOP
- 1. Objective
- 2. Scope
- 3. Responsibility
- 4. Procedure
- 5. Training
- 6. Distribution
- 7. Annexures
- 8. References
- 9. Revision history
- Frequently asked questions
- Is a status label the same as a product label?
- Do status labels replace cleaning records?
- What happens to excess printed labels after a batch?
- References
In short: This example SOP lists the status labels used on equipment, areas, containers and materials in a manufacturing plant, and who is responsible for applying and checking them. It is a template to adapt to your own quality system. Note that regulators also control product labels and printed packaging, which are covered separately below.
“Label control” covers two different things, and mixing them up is a common source of gaps in SOPs. Status labels tell staff what condition equipment, an area or a material is in (cleaned, under maintenance, rejected). Product labels and printed packaging materials carry the legal information on the pack and need much stricter control, because a mix-up can reach a patient.
What the regulators expect
- Status labelling. EU GMP Part I Chapter 5 (5.21) lists cleaning status labels on equipment and areas, together with detailed cleaning records, among the measures to prevent cross-contamination.
- Printed packaging materials and labels. Chapter 5 (5.46) asks for particular attention to printed materials: store them securely to exclude unauthorised access, keep cut labels and other loose printed materials in separate closed containers, and issue them only to authorised personnel under an approved, documented procedure. Each delivery or batch gets its own reference number (5.47), and outdated or obsolete printed material is destroyed and the disposal recorded (5.48).
- Packaging line. Before packaging starts the line is cleared of previous products, materials and documents, using a checklist (5.50). The product name and batch number are displayed at each packaging station (5.51), materials are checked on delivery to packaging (5.52), and a significant reconciliation discrepancy is investigated before release (5.61). Unused batch-coded materials are destroyed and recorded (5.62).
- US FDA. 21 CFR 211.122 requires written procedures for receipt, storage and testing of labelling, separate and identified storage for each product, restricted access, rejection of non-conforming material and destruction of obsolete labels. 21 CFR 211.125 requires strict control of issued labelling, checking against the master record, reconciliation, destruction of excess labelling that bears lot numbers, and written issuance procedures. 21 CFR 211.130 requires line clearance before use, documented in the batch record, and separation of packaging operations of different products.
Example SOP
This example SOP is an illustration. Label formats and approvals are site choices.
1. Objective
To lay down the procedure for the use and control of status labels in the production area.
2. Scope
Applies to status labels used on equipment, containers, areas and materials at the manufacturing facility. Product labels and printed packaging materials are controlled under the packaging materials and packaging operations SOPs.
3. Responsibility
- Authorised designee of the user department: applies and maintains status labels in the department.
- Head of the user department: ensures labelling is followed.
- Head QA: approves this SOP and the label formats.
4. Procedure
4.1 Types of status labels
| Label | When it is used | Annexure |
|---|---|---|
| In process | Product is in the production cycle and ready for the next stage; attached to the batch record | I |
| Under process | Machine, product or area is in operation | II |
| To be cleaned | Machine, container or area after a processing stage is finished | III |
| Cleaned | Area, container or equipment cleaned and ready for use; attached to the batch record | IV |
| Under fumigation | Area is being fumigated | V |
| Under maintenance | Equipment is with engineering for maintenance | VI |
| Rejected | Material or equipment not to be used; to be removed or discarded as per procedure | VII |
| Disinfectant / sanitiser / cleaning agent | Disinfectant, sanitiser and cleaning solutions, for example for punch cleaning | VIII |
| Excess material returned | Excess material returned from packaging to stores | IX |
| Use for | Equipment, container or accessories ready for use for a named product/batch | X |
| Bulk finished product | Bulk released by QC for the next stage or packing | XI |
4.2 General rules
- Only the current approved label formats are used. Labels are printed or issued in a controlled way, not photocopied or handwritten ad hoc.
- Only one status label is displayed on an item at a time. The old label is removed when the status changes.
- The label carries the item or area ID, product and batch (where relevant), date, and the signature of the person applying it.
- Items labelled “Rejected” are segregated, with access restricted, until disposal is documented.
- The designee of the personnel and administration department checks the disinfectant container for the solution and its status label, and records it in the daily log for filling and checking of disinfectant bottles (Annexure XII).
- Status labels attached to batch records are kept with the batch record for at least 1 year after the expiry date of the respective product batch (EU GMP Part I Chapter 4, 4.11; 21 CFR 211.180(a)), or longer if local law or the marketing authorisation requires.
5. Training
- Trainer: Head QA or designee.
- Trainees: QA, QC, Production, Packaging, Stores, Microbiology and personnel and administration staff.
6. Distribution
Controlled copies to QA, Production, QC, Packaging, Stores, Microbiology and Personnel and Administration; the original stays with QA.
7. Annexures
Annexure I In process; II Under process; III To be cleaned; IV Cleaned; V Under fumigation; VI Under maintenance; VII Rejected; VIII Disinfectant/sanitiser/cleaning agent; IX Excess material returned; X Use for; XI Bulk finished product; XII Daily log for filling and checking of disinfectant bottles.
8. References
EU GMP Part I Chapter 5; 21 CFR 211.122, 211.125 and 211.130; site quality manual.
9. Revision history
| Sr. No. | Revision No. | Change control No. | Details of revision | Reason for revision |
|---|---|---|---|---|
| 1 | 00 | ----------- | New SOP | New SOP |
Frequently asked questions
Is a status label the same as a product label?
No. Status labels show the condition of equipment, areas or materials inside the plant. Product labels are part of the pack and fall under labelling control rules (21 CFR 211.122 and 211.125; EU GMP Chapter 5).
Do status labels replace cleaning records?
No. EU GMP Chapter 5 lists status labels as an addition to detailed cleaning records, not a substitute.
What happens to excess printed labels after a batch?
Unused batch-coded packaging materials are destroyed and the destruction recorded (EU GMP 5.62), and excess labelling bearing lot or control numbers is destroyed under 21 CFR 211.125(d).
See also: Guidelines on packaging for pharmaceutical products, Good documentation practice for packaging materials specifications and retention of documents and SOP on cleaning validation.
References
- European Commission, EudraLex Volume 4, EU GMP Part I Chapter 5: Production (13 August 2014, in operation from 1 March 2015), 5.21, 5.46 to 5.52, 5.61 and 5.62.
- European Commission, EudraLex Volume 4, EU GMP Part I Chapter 4: Documentation, 4.11.
- 21 CFR 211.122 Materials examination and usage criteria; 211.125 Labeling issuance; 211.130 Packaging and labeling operations; 211.180(a) General requirements (records), ecfr.gov.
Related articles
GMP Self-Inspection Checklist (Free Printable)
Free printable GMP self-inspection checklist for pharma plants: 8 areas, 60+ yes/no checks mapped to EU GMP chapters and 21 CFR 211 sections.
QA Officer in Pharma: Role, Career Path and Salary in India
What a pharma QA officer does, the qualifications needed, the typical career ladder, how freshers get the first job and what drives QA salary in India.
FDA Warning Letter: Pfizer Healthcare India (2020)
Review FDA’s 2020 Pfizer Healthcare India warning letter, findings on sterility testing, environmental monitoring and data integrity, and the 2023 closeout.
Critical Quality Attributes in Tablet Compression
Which critical quality attributes (CQAs) matter at the tablet compression stage, how they link to press parameters, and how to monitor weight, hardness and friability.