Performance Qualification (PQ) Protocol and Report Format
Contents
- What is performance qualification?
- What the protocol and report must achieve
- Example PQ protocol format
- Header and approval
- 1. Objective
- 2. Scope
- 3. Responsibilities
- 4. Materials, equipment and documents
- 5. Procedure (example in-house criteria)
- 6. Evaluation
- Chart 1: summary data record
- Chart 2: calculations and statistical analyses
- Chart 3: acceptance criteria against results
- Deviation report
- Example PQ report content
- Record retention
- Frequently asked questions
- Is PQ always done after OQ?
- How many runs does PQ need?
- Is PQ the same as process validation?
- Can acceptance criteria be changed during execution?
- References
In short: Performance qualification (PQ) is the last qualification stage for equipment, utilities and systems. It shows, with documented evidence, that the item performs effectively and reproducibly in real use. This page explains what regulators expect and gives an example protocol and report format that you must adapt to your own quality system.
What is performance qualification?
EU GMP Annex 15 (Qualification and Validation, 2015) defines PQ as the documented verification that systems and equipment can perform effectively and reproducibly, based on the approved process method and product specification. PQ normally follows successful installation qualification (IQ) and operational qualification (OQ). In some cases it may be appropriate to run PQ together with OQ or with process validation (Annex 15, section 3.13).
Annex 15, section 3.14, says PQ should include, but is not limited to:
- tests using production materials, qualified substitutes or simulated product that behaves equivalently under normal operating conditions, at worst-case batch sizes, with the sampling frequency used to confirm control justified; and
- tests covering the operating range of the intended process, unless development data already document the operating ranges.
Annex 15 does not fix a number of runs or days for PQ. You decide, justify and write down the extent of testing in the protocol, based on risk and process knowledge.
See also: Installation Qualification (IQ) protocol and report, Operational Qualification (OQ) protocol and report and Qualification stages for equipment, facilities, utilities and systems.
What the protocol and report must achieve
Annex 15, section 2, sets the documentation expectations that apply to PQ as to any other validation work:
- The protocol defines the critical systems, attributes and parameters and the associated acceptance criteria (2.4).
- All qualification documents are approved by the personnel defined in the pharmaceutical quality system (2.2).
- A significant change to the approved protocol during execution, such as to acceptance criteria or operating parameters, is documented as a deviation and scientifically justified (2.7).
- A result that fails a pre-defined acceptance criterion is recorded as a deviation and investigated under local procedures; its implications are discussed in the report (2.8).
- The report summarises the results against the acceptance criteria, justifies any later change to those criteria, and ends with a final recommendation on the outcome (2.9).
- Release to the next stage is formally authorised, and conditional approval is possible only where there is a documented assessment of no significant impact (2.10).
Example PQ protocol format
This is an illustrative template. Replace the bracketed items and the example criteria with those from your own approved validation master plan and risk assessment. See also Validation Master Plan.
Header and approval
| Field | Entry |
|---|---|
| Protocol number | |
| Title | Performance Qualification of [equipment or system] |
| Facility | |
| Page | ___ of ___ |
| Written by / date | |
| Department approval / date | |
| QA approval / date |
1. Objective
To demonstrate that the [equipment or system] performs as intended and consistently meets its predetermined specifications when run on its intended schedule under normal conditions and, where appropriate, under worst-case conditions, with all relevant data recorded.
2. Scope
PQ is carried out after IQ and OQ are complete and approved. It is repeated or partly repeated after installation, relocation or a change assessed as needing requalification, and at intervals justified in the validation master plan (Annex 15 section 4 expects equipment and systems to be re-evaluated at an appropriate frequency).
Example in-house practice: where one system supplies another during qualification, the supplying system is qualified first. An example is a purified water system before a pure steam generator, and the steam generator before an autoclave that uses it.
3. Responsibilities
| Role | Responsibility |
|---|---|
| Operator or user department | Runs the system or equipment and records the data |
| Supervisor | Supervises the study, checks the records are complete, writes the deviation report and the PQ report |
| Quality Assurance | Reviews and approves the protocol, the deviations and the report |
4. Materials, equipment and documents
List and attach copies of:
- the SOPs for normal operation of the system under test, including data record forms, charts, diagrams, and materials and equipment needed; and
- the SOPs specific to the performance tests, including data forms, calculations, statistical analyses, and the predetermined specifications and acceptance criteria.
5. Procedure (example in-house criteria)
| Item | Example approach |
|---|---|
| Equipment | Run the normal process three times for each use (configuration or load), recording all required data and any deviation from the procedure |
| Utility or system | Run for 20 consecutive working days, recording all required data and any deviation |
These run counts and the 20-day period are example in-house criteria, not regulatory requirements. Justify your own choice (for example using risk, variability and process knowledge) in the protocol.
6. Evaluation
- Attach all completed, signed data record forms.
- Complete the summary data record (Chart 1).
- Perform all required calculations and statistical analyses (Chart 2).
- Compare results with the acceptance criteria (Chart 3).
- Write a deviation report with justification and impact assessment.
- Write the PQ report.
- Submit the full PQ package to QA for review and approval.
Chart 1: summary data record
Prepare this for the specific procedure under test. Include performed by / date and verified by / date lines.
Chart 2: calculations and statistical analyses
Record each calculation, the method used, the result, and performed by / verified by lines with dates.
Chart 3: acceptance criteria against results
| Criterion (from protocol) | Result | Pass / Fail |
|---|---|---|
Deviation report
| Section | Content |
|---|---|
| Deviation(s) | Describe each, with its reference number |
| Justification for acceptance | Scientific reason the result can be accepted, or the corrective action |
| Impact on operation, function or process | Effect on product quality, validated state and later qualification stages |
| Written by / verified by | Names, signatures and dates |
Example PQ report content
The PQ report should include:
- date the study started and date it finished;
- observations made and problems encountered;
- completeness of the information collected;
- a summary of the deviation report;
- results of every test and whether each met its acceptance criterion;
- location of the original data;
- any other relevant information; and
- a conclusion on whether the equipment or system is qualified, with a recommendation on release for use.
The report is written and verified by named persons with dates, then approved by Quality Assurance.
Record retention
Keep the signed protocol, raw data and report under your document control system. Where qualification data support the release of batches, retain them for at least 1 year after the expiry date of the respective product batch (EU GMP Part I Chapter 4 section 4.11, or 5 years after QP certification if longer; also 21 CFR 211.180(a)), and longer if local law or the marketing authorisation requires.
Frequently asked questions
Is PQ always done after OQ?
Normally yes. Annex 15 says PQ should normally follow IQ and OQ, but allows it to be performed together with OQ or process validation when that is justified.
How many runs does PQ need?
No regulation gives one number. The protocol must justify the number and duration, based on risk, process variability and prior knowledge.
Is PQ the same as process validation?
No. PQ shows that equipment or a system performs reproducibly. Process validation shows that the manufacturing process gives product meeting its specification and quality attributes.
Can acceptance criteria be changed during execution?
Only as a documented deviation with scientific justification, as described in Annex 15 section 2.7. Do not adjust criteria after seeing results without that justification.
References
- European Commission, EudraLex Volume 4, EU GMP Guidelines, Annex 15: Qualification and Validation (2015), sections 2, 3.13, 3.14 and 4, plus the glossary definition of PQ.
- European Commission, EudraLex Volume 4, Part I, Chapter 4: Documentation (revision effective 30 June 2011), section 4.11.
- US FDA, 21 CFR 211.180(a), General requirements (records retention).
- WHO, Quality Assurance of Pharmaceuticals, Volume 2 (as cited by the original article).
Related articles
Guidelines on Packaging for Pharmaceutical Products (WHO TRS 902)
Plain-language summary of the WHO guidelines on packaging for pharmaceutical products: functions, materials, closures, labels, QA and packaging-line controls.
Microbial Contamination of Compressed Air in Pharma
How microbial contamination of compressed air happens in pharma plants, and how to control and monitor it using EU GMP Annex 1 rules for product-contact gases.
Qualification Stages: URS, DQ, FAT/SAT, IQ, OQ and PQ
Understand the qualification stages for equipment, facilities, utilities and systems: URS, DQ, FAT/SAT, IQ, OQ, PQ and re-qualification under EU GMP Annex 15.
SOP for Handling of Artwork in Pharma Packaging
Example SOP for handling artwork of printed packaging materials: preparation, approval, shade cards, revision, retrieval and destruction, with the GMP basis.